MRCC¶
Interface to MRCC program written by Mihály Kállay.
General¶
E_CONVERGENCE¶
Convergence criterion for energy. See Table Post-SCF Convergence for default convergence criteria for different calculation types. This becomes
tol
(option #16) in fort.56.
- Type: conv double
- Default: 1e-6
INTS_TOLERANCE¶
Minimum absolute value below which integrals are neglected.
- Type: conv double
- Default: 1.0e-12
MRCC_LEVEL¶
Maximum excitation level. This is used ONLY if it is explicitly set by the user. Single-reference case: all excitations up to this level are included, e.g., 2 for CCSD, 3 for CCSDT, 4 for CCSDTQ, etc. This becomes
ex.lev
(option #1) in fort.56.
- Type: integer
- Default: 2
MRCC_NUM_DOUBLET_ROOTS¶
Number of root in case of open shell system. This becomes
ndoub
(option #13) int fort.56.
- Type: integer
- Default: 0
MRCC_NUM_SINGLET_ROOTS¶
Number of singlet roots. (Strictly speaking number of of roots with M_s=0 and S is even.) Use this option only with closed shell reference determinant, it must be zero otherwise. This becomes
nsing
(option #2) in fort.56.
- Type: integer
- Default: 1
MRCC_NUM_TRIPLET_ROOTS¶
Number of triplet roots. (Strictly speaking number of of roots with \(M_s=0\) and S is odd.) See notes at option MRCC_NUM_SINGLET_ROOTS This becomes
ntrip
(option #3) in fort.56.
- Type: integer
- Default: 0
Expert¶
MRCC_METHOD¶
If more than one root is requested and calc=1, LR-CC (EOM-CC) calculation is performed automatically for the excited states. This overrides all automatic determination of method and will only work with
energy()
. This becomesCC/CI
(option #5) in fort.56. See Table MRCC_METHOD for details.
- Type: integer
- Default: 1
MRCC_OMP_NUM_THREADS¶
Sets the OMP_NUM_THREADS environment variable before calling MRCC. If the environment variable
OMP_NUM_THREADS
is set prior to calling Psi4 then that value is used. When set, this option overrides everything. Be aware the-n
command-line option described in section Threading does not affect MRCC.
- Type: integer
- Default: 1
MRCC_RESTART¶
The program restarts from the previously calculated parameters if it is 1. In case it is 2, the program executes automatically the lower-level calculations of the same type consecutively (e.g., CCSD, CCSDT, and CCSDTQ if CCSDTQ is requested) and restarts each calculation from the previous one (rest=2 is available only for energy calculations). Currently, only a value of 0 and 2 are supported. This becomes
rest
(option #4) in fort.56.
- Type: integer
- Default: 0