CFOUR_VIBRATION


Specifies whether (harmonic) vibrational frequencies are calculated or not. If the default NO (=0) is specified then no frequencies are calculated. For ANALYTIC, vibrational frequencies are determined from analytically computed second derivatives, and for FINDIF (=2) vibrational frequencies are calculated from a force field obtained by numerical differentiation of analytically evaluated gradients (or even single-point energies) using symmetry-adapted mass-weighted Cartesian coordinates. If vibrational frequencies are calculated, a normal mode analysis using the computed force-constant matrix is performed, rotationally projected frequencies are computed, infrared intensities are determined, and zero-point energies (ZPE) are evaluated.

  • Type: string
  • Possible Values: NO, ANALYTIC, FINDIF, EXACT
  • Default: NO